The larger engineering issue is straightforward. A radio cannot provide a trustworthy battery alarm until it can identify which source a reading belongs to, decode the value correctly, and tell a fresh value from a stale one. A convincing label or a displayed voltage unit does not establish any of those properties. EdgeTX issue #8049 and issue #8050 make the failure modes concrete.
One displayed name can refer to two physical packs
The dual-battery report describes two sensor entries named RB1V, with corresponding duplicates for current and consumed capacity. The reporter isolated the connections: unplugging one receiver battery made the sensor displayed as 1804 disappear; unplugging the other removed 180A. Those distinct identifiers matter even though the visible names are the same. They suggest that two physical sources are reaching the radio and that the ambiguity is at least partly in the mapping to human-readable labels.
The EdgeTX Spektrum telemetry decoder maps entries in the dual receiver-battery message to names and units. The reporter points to a table in which the second group of battery fields is also labeled with the first battery's name constants. That is a concrete place for maintainers to inspect. It does not, on its own, prove which builds contain a bug or whether changing the labels would correct every downstream use.
A display name is also a poor substitute for a sensor identity. EdgeTX's telemetry configuration documentation distinguishes discovered sensors, their identifiers and instances, and their display behavior. Two names that look identical to a pilot need not refer to the same underlying sensor record. Conversely, two different names are no guarantee that each reading is attached to the intended physical connector.
For a redundant receiver-power arrangement, that distinction has operational consequences. An alarm intended for battery 2 can be connected to battery 1's telemetry channel, or a widget can display the first match to a duplicated name. The model may still operate normally while its warning configuration is misleading.
Voltage decoding is a separate failure path
The companion report gives two particularly useful comparisons. The author says a voltmeter measured 8.16 V on one battery and 6.06 V on the other, while the transmitter displayed 117.79 V and 235.54 V. The reporter suspects a mismatch between big-endian values in Spektrum data and the little-endian interpretation in EdgeTX, and offers a Lua byte-swapping workaround.
That is a plausible diagnostic hypothesis, not a confirmed root-cause analysis. A 16-bit field can be wrong because of byte order, but also because of an incorrect field offset, signedness, scale, calibration or parsing of the wrong sensor. The four observed numbers are enough to establish a serious discrepancy in that particular setup. They are not sufficient to show that a universal byte swap is the right fix.
The Spektrum decoder source identifies the receiver-battery telemetry message and its field mapping. The next useful test is to capture or instrument the raw incoming bytes, identify the relevant fields from the protocol definition, and compare their decoded integer values with the voltmeter. Only then should a patch choose the required byte order and scaling. A screen that says V can still be displaying the wrong number.
The author's Lua example demonstrates a potential diagnostic route, not a verified safety correction. EdgeTX exposes setTelemetryValue with explicit identifier, sub-ID, instance, unit and precision arguments. A derived sensor created by a script therefore needs its own unambiguous identity. If an improvised script publishes a corrected-looking figure under a second name, a model's existing alarm may still read the original channel. A Lua workaround also needs independent validation for missing data, startup values and unexpected input.
Trace the data to the alarm, not merely to the screen
The complete chain is longer than the two visible voltage values:
- A physical battery feeds a particular receiver power input, which has its own sensing circuitry.
- The receiver constructs telemetry fields; a multiprotocol RF module transports them toward the radio.
- The radio's decoder maps message type and field position into a sensor identifier, name, unit and value.
- The telemetry store updates that sensor. A widget, audio announcement, logical switch or alarm then consumes a selected channel.
A fault at any step can look like a battery problem on the last screen. The label issue and voltage issue may occur together without sharing one cause. Likewise, a correctly decoded reading may be outdated if the telemetry source stops reporting.
The EdgeTX user manual describes how discovered telemetry is used in widgets, alarms and voice callouts. That makes the alarm's source selection part of the acceptance test. Verify the selected sensor's identity and update behavior, not just its displayed string. Keep receiver battery and propulsion battery telemetry conceptually separate: they may measure different electrical paths, and a healthy receiver voltage does not certify the main flight pack.
A bench sequence for two battery inputs
A controlled bench test can separate identity errors from conversion errors without taking an aircraft airborne. Remove propellers or otherwise make propulsion physically safe before energizing and reconnecting equipment, and follow the receiver's approved power-input arrangements.
- Record the baseline. Save the radio firmware version, multiprotocol module firmware, receiver model and firmware, telemetry sensor list and existing alarm sources. Measure each input with an appropriate meter. Do not overwrite the previous model configuration merely to test discovery.
- Identify each input. With the receiver safely powered, vary or disconnect one monitored input at a time using the equipment's supported procedure. Record which sensor identifier changes or stops updating. Repeat for the other input. The November report's
1804and180Aobservations are an example of this isolation method, not universal IDs for every receiver. - Validate the numbers. Compare each radio reading against several known voltages inside the specified operating range. A single plausible value can conceal a scale or byte-order mistake. Log raw telemetry if possible and check units, field boundaries and decoding.
- Exercise the warnings. Test battery-1-low and battery-2-low cases separately; then test loss of updates and recovery. Check the widget, spoken callout, logical switch and any recorded log that the pilot actually uses. Determine whether a stale reading retains its last numerical value and how that state is announced.
- Recheck after changes. A firmware update, sensor rediscovery or renamed field can alter the connection between a displayed label and a saved alarm. Repeat the source-to-alarm checks after changes.
These tests establish behavior for one hardware and software combination. They are not a flight-worthiness certificate. Redundant packs also need their own power-path and load-sharing validation; telemetry only observes selected aspects of that system.
What would make a firmware correction credible?
A narrow display-label fix should show that the first and second battery fields produce distinguishable sensor names and stable sensor identities after discovery, model save, reboot and module reconnect. It should preserve compatibility with existing saved sensors or document any migration behavior. A voltage-decoding fix needs captured test vectors with known payload bytes and expected physical readings, including boundary values and multiple battery levels.
The two fixes should be tested independently. A regression test that checks the text RB2V cannot prove that the number behind it is right. A test that checks a correctly decoded 6.06 V cannot prove that the alarm listens to battery 2. Both cases belong in an end-to-end telemetry test, ideally including timeout behavior.
The two reports from 13 November do not establish whether the issues have since been fixed on all supported firmware branches. Before a pilot relies on warnings for either receiver pack, the practical evidence is a traceable physical input, a correct decoded number, a fresh update and an alarm wired to that exact source. Those four conditions are independently testable; the label on the display is not a shortcut.