ArduPilot proposes restoring RC UART ownership after serial passthrough
ArduPilot PR 34994, opened 4 November, describes SBUS RC input remaining silent after the same UART is used for serial passthrough on ChibiOS. The proposal reopens the port from the RC input thread when passthrough ends; a mock-UART test in the PR reports recovery within 200 ms.
Wed, 4 Nov 2026
Servicing or flashing a receiver through serial passthrough should not silently leave the pilot's control input disconnected until reboot.
The change is unmerged and not yet hardware-tested in the PR. Verify RC-channel recovery and failsafe state after passthrough on the precise controller and firmware you use.